Product Description
Features:
● Digital key input, the accurate and quick operation
● It Can run independently, also can be combined together
● Use any brand standard syringe and automatic identification syringe specification
● The integration of environmental design, prevent the liquid leakage inside
Specifications:
● Safety Control: multi-supervision technology, self-test when turn-on and real-time self-test when infusing
● Display: 320*240Dot-matrix LCD
● Applicable Syringes: 5ml,10ml, 20ml, 30,50ml, Auto-recognize
● Flow Rate Range:
5ml syringe 1ml/h~200ml/h
10ml syringe 1ml/h~300ml/h
20mlsyringe 1ml/h~400ml/h
30mlsyringe 1ml/h~600ml/h
50ml syringe 1ml/h~1200ml/h
● Flow Rate Accuracy:±2% (Mechanical Accuracy ±1%)
● Limited Volume Range:0.1~9999.9ml
● Infused Volume Display:0.1~9999.9ml
● Applicable Syringes Brand: Preset 15 Kinds, and user added
● Purge Rate:
5ml syringe 200ml/h
10mlsyringe 300ml/h
20mlsyringe 400ml/h
30mlsyringe 600ml/h
50mlsyringe 800ml/h
● Bolus Flow Rate Range:
5ml syringe 1ml/h~200ml/h
10ml syringe 1ml/h~300ml/h
20ml syringe 1ml/h~400ml/h
30ml syringe 1ml/h~600ml/h
50ml syringe 1ml/h~1200ml/h
● KVO Flow Rate:1.0~5.0ml/h
● Body Weight/Drug Mode Rate:
10 Optional(ml/h,ml/min,mg/h,ug/h,mg/min,ug/min,mg/kg/h,mg/kg/min,ug/kg/h,ug/kg/min)
● OcclusionPressure:8 Level Sensitivity,20~140KPa,DynamicPressure
● Alarms: Syringe dislocated, Syringe handspike Err., Pre-alarm of completed limited volume,
Completed limited volume, Near empty, Empty, Occlusion, Bolus volume finished, Low battery,
Battery empty, Reminder alarm
● Power Supply: AC 100~240V,50/60Hz,Powerconsumption ≤20VA
● Internal Battery: Ni-MH,12V,800mAh(or Li,11.1V,1800mAh)
● BatteryOperation:3.0 (or 7) Hours at 25ml/h
● Classification: Class I, Internal power supply, CF type, IPX4
● Data Communication Interface: wireless (accessories)
● Operating Conditions: Temperature +5℃~+40℃,Relativehumidity 20%~95%
Reviews
There are no reviews yet.