COMMON FEATURES
Operating Modes: Pneumatically driven & electronically controlled, closed,
semi-closed and semi-open
Pneumatically driven electrically controlled ventilator, can be used for emergency clinical resuscitation and respiratory therapy
Nonhazardous environmentally friendly frame, precise construction, elegant design, equipped with automated self-checking function during startup and an
automatic self-calibrating sensor
Display: Built-in 10.4 inch high visibility color TFT display, able to simultaneously
display Pressure-Time and Flow-Time waveforms in real time
Sigh: Ability to insert 1-8 sigh breaths in every 100 breaths, ventilation should be
no less than 1.5 the tidal volume
Equipped with infrared turbine flow sensor; precisely measures gas flows, stable
and reliable
Power Failure Support Functions: Automatically converts-standby mode during
AC power outages
9 Level adjustable humidifier
Monitor Parameters: tidal volume, respiration rate, airway pressure, I:E ratio, inspiratory & expiratory status, inspiratory trigger and others
Alarms: Audible and/or visual alarms for ventilation volume, tidal volume, oxygen
concentration, asphyxia, airway pressure, intubation disconnection, low oxygen,
power failure and other alarms, also features a alarm history query function
ADVANCED MODEL EXCLUSIVE FEATURES
Equipped with professional medical grade air compressor tailored for long clinical times and low noise requirements
AIR COMPRESSOR
Air Compressor: 220V AC±10%, 50±1Hz, 700VA, also features good protective
grounding against electrical activity
Output Gas Pressure: 0.4MPa±20%
Continuous output gas flow greater than or equal to 20L/min
Instantaneous output gas flow great than or equal to 60L/min
Specifications:
▅ Display: 10.4 inch high visibility color TFT display
▅ Ventilation Mode: A/C, IPPV, SIPPV, IMV, SIMV, Standby, SPONT MANUAL
▅ Minute Volume: Greater than or equal to 18L
▅ Back-up Power Supply: At least 4 hours
▅ Tidal Volume: Adjustable range: 50-1500ml / Display range: 0-2000ml
▅ Respiratory Rate: 1-99bpm
▅ Inspiratory/expiratory (I:E) Ratio: 4 ;1-1 ;4
▅ PEEP: 0-10cmH2O
▅ SIMV Rate: 1-20bpm
▅ Inspiratory Pressure Trigger: -10-10cmH2O
▅ Inspiratory Plateau: Adjustable from 0-50% of inspiratory time
▅ Adjustable Oxygen Concentration: 21-100%
▅ Gas Supply Requirement: 280~600 kPa medical grade oxygen and compressed air supply
▅ Maximum Safe Operating Pressure: ≤6.0kPa
▅ Tidal Volume Alarm: Upper Limit: 10~2000ml, Lower Limit: 0~1800ml
▅ Airway Pressure Alarm: Upper Limit: 0.1~6kPa, Lower Limit: 0~5kPa
▅ Oxygen Concentration Alarm: Upper Limit: 22~100%, Lower Limit: 21~80%