Defibrillator PT-9000C Details

Defibrillator PT-9000C
REF: MEN-2026-0475

Emergency Room

Defibrillator PT-9000C

Sold & Shipped By Official Store
Price on Request
Product Code MEN-2026-0475
Condition New
Availability On request
Warranty
Sub-Category
1. Portable main unit design for easy movement and emergency use
2. Supports Manual, Synchronized, and Asynchronized defibrillation modes
3. Wide energy selection from 0 to 360 Joules
4. Reusable adult paddles with integrated pediatric paddles
5. High-resolution 7-inch color LCD display
6. Multi-parameter patient monitoring including ECG, RESP, SpO₂, NIBP, Temperature, and Pulse Rate
7. Arrhythmia analysis and ST-segment analysis
8. Thoracic impedance respiration monitoring
9. Automatic oscillometric NIBP measurement with manual/automatic/stat modes
10. Pulse oximetry monitoring with waveform and histogram display
11. Rechargeable internal battery backup with LED charging indicator
12. AC power and optional vehicle DC power support
13. Optional recorder and Li-ion battery upgrade
General
1. Model: PT-9000C
2. Type: Portable Defibrillator
3. Dimensions: 320 × 205 × 410 mm
4. Weight: 9.8 kg
Defibrillator
1. Defibrillation Type: Manual / Synchronized / Asynchronized
2. Energy Accuracy: ≤ ±1%
3. Energy Levels: 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 J (at 50Ω resistance)
4. Charging Time: ≤ 10 seconds to 360 J
5. Paddles: Reusable adult paddles with integrated pediatric paddles
Power Requirements
1. AC Power Supply: 100–240 V, 50/60 Hz
2. Vehicle Voltage (Optional): DC 12 V
Internal Battery
1. Battery Type: Rechargeable Lead-Acid (12 V 2.0 Ah ×2)
2. Charging Time: Minimum 4 hours for full charge
3. Charging Mode: Charges during AC power operation
4. Battery Indicator: Red LED for charging/low battery
Battery Capacity:
1. Up to 120 minutes monitoring
2. 35 discharges at 360 J
Display
1. Screen Size: 7-inch LCD
2. Type: High-resolution true color graphic
3. Resolution: 480 × 234
ECG
1. Leads: I, II, III, aVR, aVL, aVF, V1–V6
2. ST Segment Analysis: −2.0 to 2.0 mV
3. Arrhythmia Analysis: Yes
4. Protection: Withstand 4000 VAC/50 Hz isolation; resistant to electrosurgical interference and defibrillation
Respiration
1. Measurement Method: Thoracic impedance
NIBP
1. Working Modes: Manual / Automatic / STAT (5 minutes)
2. Method: Automatic oscillometric
3. Cuff Type: Standard adult; optional pediatric and neonatal
Temperature
1. Measurement Range: 20 – 45 °C
2. Resolution: 0.1 °C
Pulse Oximetry (SpO₂)
1. Display: SpO₂ value, pulse waveform, histogram, pulse rate
2. Range: 0 – 99% (adult, pediatric, neonatal)
3. Probe: Adult finger clip (standard)
4. Optional Probes: Pediatric Y-type clip, neonatal wrap
Pulse Range
1. Range: 0 – 255 bpm
Standard Parameters
1. ECG / RESP / SpO₂ / TEMP / PR / NIBP / Defibrillator
Optional Parameters
1. Recorder
2. Li-ion battery (11.1 V 4 Ah ×2)
Operation manuals are available upon request during delivery.